Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.513
Filtrar
1.
Crit Care Sci ; 36: e20240235en, 2024.
Artigo em Inglês, Português | MEDLINE | ID: mdl-38597484

RESUMO

BACKGROUND: Newborn infants admitted to the neonatal intensive care unit require arterial cannulation for hemodynamic monitoring and blood sampling. Arterial access is achieved through catheterization of umbilical or peripheral arteries. Peripheral artery cannulation is performed in critically ill newborns, but artery localization and cannulation is often challenging and unsuccessful. Therefore, increasing the internal diameter and preventing vasospasm are important for successful peripheral artery cannulation in neonates. Topical glyceryl trinitrate has the potential to increase cannulation success by relaxing arterial smooth muscles and thus increasing the internal diameter. We aim to conduct a pilot randomized controlled trial to evaluate the efficacy and safety of topycal glyceryl trinitrate in increasing the diameter of the radial artery in neonates. METHODS/DESIGN: This study will be a single-center, observer-blind, randomized, placebo-controlled trial conducted in the neonatal intensive care unit of Perth Children's Hospital, Western Australia. A total of 60 infants born at >34 weeks of gestation who are admitted for elective surgery or medical reasons and for whom a peripheral arterial line is needed for sampling or blood pressure monitoring will be recruited after informed parental consent is obtained. The primary outcome will be the change in radial arterial diameter from baseline to postintervention. Secondary outcomes will be the absolute and percentage change from baseline in the radial arterial diameter in both limbs and safety (hypotension and methemoglobinemia). DISCUSSION: This will be the first randomized controlled trial evaluating the use of topical glyceryl trinitrate to facilitate peripheral artery cannulation in neonates. If our pilot randomized controlled trial confirms the benefits of glyceryl trinitrate patches, it will pave the way for large multicenter randomized controlled trials in this field.


Assuntos
Cateterismo Periférico , Nitroglicerina , Lactente , Criança , Humanos , Recém-Nascido , Nitroglicerina/uso terapêutico , Artéria Radial , Cateterismo Periférico/efeitos adversos , Austrália Ocidental , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
2.
Comput Methods Programs Biomed ; 249: 108146, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38593514

RESUMO

BACKGROUND AND OBJECTIVE: In the current work, we present a descriptive fluid-structure interaction computational study of the end-to-side radio-cephalic arteriovenous fistula. This allows us to account for the different thicknesses and elastic properties of the radial artery and cephalic vein. METHODS: The core of the work consists in simulating different arteriovenous fistula configurations obtained by virtually varying the anastomosis angle, i.e. the angle between the end of the cephalic vein and the side of the radial artery. Since the aim of the work is to understand the blood dynamics in the very first days after the surgical intervention, the radial artery is considered stiffer and thicker than the cephalic vein. RESULTS: Our results demonstrate that both the diameter of the cephalic vein and the anastomosis angle play a crucial role to obtain a blood dynamics without re-circulation regions that could prevent fistula failure. CONCLUSIONS: When an anastomosis angle close to the perpendicular direction with respect to the radial artery is combined with a large diameter of the cephalic vein, the recirculation regions and the low Wall Shear Stress (WSS) zones are reduced. Conversely, from a structural point of view, a low anastomosis angle with a large diameter of the cephalic vein reduces the mechanical stress acting on the vessel walls.


Assuntos
Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Humanos , Derivação Arteriovenosa Cirúrgica/métodos , Velocidade do Fluxo Sanguíneo , Artéria Radial , Diálise Renal , Resultado do Tratamento
3.
Sensors (Basel) ; 24(7)2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38610298

RESUMO

Radial pulse diagnosis is the most common method to examine the human health state in Traditional East Asian Medicine (TEAM). A cold stress-related suboptimal health state (subhealth) is often undetectable during routine medical examinations, however, it can be detected through the palpation of specific pulse waves, particularly a 'tight pulse', in TEAM. Therefore, this study examined a correlation between 'tight pulse' and vascular changes in the radial artery (RA) induced by a cold pressor trial (CPT). Twenty healthy subjects underwent sequentially control trial and CPT with room-temperature and ice-cold water, respectively, on the right forearm. The radial pulse and vascular changes were then examined on the left arm. The radial pulse scores for frequencies of 'tight pulse' with strong arterial tension increased after the CPT compared with the control trial. The pulse scores were reversely correlated with the RA thickness and volumes in ultrasonography, but not with changes in the systolic/diastolic blood pressure. The RA thickness-based vascular surface and three-dimensional images visualized a 'tight pulse' showing the vasoconstriction and bumpy-/rope-shaped vascular changes in the radial pulse diagnostic region after the CPT. These findings provide valuable insights into the potential integration of clinical radial pulse diagnosis with ultrasonography for cold-related subhealth.


Assuntos
Artéria Radial , Diagnóstico Tradicional pelo Pulso , Humanos , Resposta ao Choque Frio , Frequência Cardíaca , Temperatura Baixa
7.
Nagoya J Med Sci ; 86(1): 155-159, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38505728

RESUMO

The radial artery has been used increasingly for percutaneous coronary intervention because of its safety and feasible access route. Nevertheless, transradial complications are possible because of the variation in radial artery anatomy. We experienced a case of the brachioradial artery injury secondary to catheterization, presenting as hypovolemic shock. A 76-year-old woman presented at our emergency department complaining of effort-induced angina. Coronary angiography via the right radial artery showed critical stenosis in the middle of the left anterior descending coronary artery. After wiring into this vessel, balloon angioplasty using a 6-Fr Judkin left guiding catheter was performed with the deployment of the zotarolimus-eluting stent. There was difficulty in negotiating the guidewire and balloons in that resistance was experienced while passing the catheter in the upper arm. Therefore, retrograde radial arteriography was performed to determine any injury to radial artery. This showed contrast extravasation in the brachioradial artery. Initially, manual compression was tried. However, 2 hours later, the patient developed cold sweating and went into a stupor. Laboratory findings showed a decline in hemoglobin, leading to suspicion of hemorrhagic shock. We applied over 30 minutes of balloon inflation, but this was ineffective. While surgical repair was not available, a 6.0 × 50 mm Viabahn stent was placed over the axillary artery. Subsequent angiography showed no further leakage or occlusion of the brachioradial artery. The postprocedural period was uneventful, and the patient was discharged with dual antiplatelet agents. At a 7-year clinical follow-up, the patient was free from limb ischemia symptoms.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Feminino , Humanos , Idoso , Stents Farmacológicos/efeitos adversos , Seguimentos , Artéria Radial , Doença Iatrogênica , Resultado do Tratamento
8.
J Cardiothorac Vasc Anesth ; 38(5): 1115-1126, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38461034

RESUMO

OBJECTIVE: Systemic systolic (SAP) and mean (MAP) arterial pressure monitoring is the cornerstone in hemodynamic management of the cardiac surgical patient, and the radial artery is the most common site of catheter placement. The present study compared 3 different arterial line procedures. It is hypothesized that a 20-G 12.7- cm catheter inserted into the radial artery will be equal to a 20-G 12.7- cm angiocath placed in the brachial artery, and superior to a 20-G 5.00 cm angiocath placed in the radial artery. DESIGN: A prospective randomized control study was performed. SETTING: Single academic university hospital. PARTICIPANTS: Adult patients ≥18 years old undergoing nonemergent cardiac surgery using cardiopulmonary bypass (CPB). INTERVENTIONS: After approval by the Rhode Island Hospital institutional review board, a randomized prospective control study to evaluate 3 different peripheral intraarterial catheter systems was performed: (1) Radial Short (RS): 20-G 5- cm catheter; (2) Radial Long (RL): 20-G 12- cm catheter; and (3) Brachial Long (BL): 20-G 12- cm catheter. MEASUREMENTS AND RESULTS: Gradients between central aortic and peripheral catheters (CA-P) were compared and analyzed before CPB and 2 and 10 minutes after separation from CPB. The placement of femoral arterial lines and administration of vasoactive medications were recorded. After exclusions, 67 BL, 61 RL, and 66 RS patients were compared. Before CPB, CA-P SAP and MAP gradients were not significant among the 3 groups. Two minutes after CPB, the CA-P SAP gradient was significant for the RS group (p = 0.005) and insignificant for BL (p = 0.47) and RL (p = 0.39). Two-group analysis revealed that CA-P SAP gradients are similar between BL and RL (p = 0.84), both of which were superior to RS (p = 0.02 and p = 0.04, respectively). At 10 minutes after CPB, the CA-P SAP gradient for RS remained significant (p = 0.004) and similar to the gradient at 2 minutes. The CA-P SAP gradients increased from 2 to 10 minutes for BL (p = 0.13) and RL (p = 0.06). Two minutes after CPB, the CA-P MAP gradients were significant for the BL (p = 0.003), RL (p < 0.0001), and RS (p < 0.0001) groups. Two-group analysis revealed that the CA-P MAP gradients were lower for the BL group compared with the RL (p = 0.054) and RS (p< 0.05) groups. Ten minutes after CPB, the CA-P MAP gradients in the RL and RS groups remained significant (p < 0.0001) and both greater than the BL group (p = 0.002). A femoral arterial line was placed more frequently in the RS group (8/66 = 12.1%) than in the RL group (3/61 = 4.9%) and the BL group (2/67 = 3.0%). Vasopressin was administered significantly more frequently in the RS group. CONCLUSION: Regarding CA-P SAP gradients, the RL group performed equally to the BL group, both being superior to RS. Regarding CA-P MAP gradients, BL was superior to RL and RS. Clinically, femoral line placement and vasopressin administration were fewer for the BL and RL groups when compared with the RS group. This study demonstrated the benefits of a long (12.7 cm) 20- G angiocath placed in the radial artery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Monitorização Hemodinâmica , Dispositivos de Acesso Vascular , Adulto , Humanos , Adolescente , Pressão Sanguínea , Estudos Prospectivos , Artéria Radial/cirurgia , Ponte Cardiopulmonar , Vasopressinas , Cânula
9.
Am J Cardiol ; 218: 34-42, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432336

RESUMO

Radial artery occlusion (RAO) is a major impediment to reintervention in patients who underwent proximal transradial access (p-TRA) for coronary catheterization. Distal transradial access (d-TRA) at the level of snuffbox distal to the radial artery bifurcation is a novel alternative to p-TRA. We conducted an updated meta-analysis of all available randomized controlled trials (RCTs) to compare the incidence of RAO between p-TRA and d-TRA, along with access site-related complications. PubMed, Web of Science, and Google Scholar were searched for RCTs published since 2017 to October 2023 comparing d-TRA and p-TRA for coronary angiography and/or intervention. Risk ratios (RRs) and mean differences (MDs) with 95% confidence intervals were calculated using the random-effects model for procedural and clinical outcomes for the 2 approaches. A total of 18 RCTs with 8,205 patients (d-TRA n = 4,096, p-TRA n = 4,109) were included. The risk of RAO (RR 0.31, 0.21 to 0.46, p ≤0.001) and time to hemostasis (minutes) (MD -51.18, -70.62 to -31.73, p <0.001) was significantly lower in the d-TRA group. Crossover rates (RR 2.39, 1.71 to 3.32, p <0.001), access time (minutes) (MD 0.93, 0.50 to 1.37, p <0.001), procedural pain (MD 0.46, 0.13 to 0.79, p = 0.006), and multiple puncture attempts (RR 2.13, 1.10 to 4.11, p = 0.03) were significantly higher in the d-TRA group. The use of d-TRA for coronary angiography and/or intervention is associated with a lower risk of RAO at the forearm and may preserve p-TRA site for reintervention in selective patients by reducing the incidence of RAO.


Assuntos
Arteriopatias Oclusivas , Intervenção Coronária Percutânea , Humanos , Angiografia Coronária/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Artéria Radial , Arteriopatias Oclusivas/epidemiologia , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 103(5): 722-730, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38469945

RESUMO

BACKGROUND: The radial first approach in cardiac catheterization is preferred for its benefits in patient comfort and recovery time. Yet, challenges persist due to characteristics like small, deep, calcified, and mobile radial arteries. Utilizing ultrasound before and during procedures can improve success rates. However, the adoption of its use is still limited and subject to debate. AIM: To utilize routine preprocedural ultrasound (US) and compare US guided with palpation guided radial access, focusing on operator efficiency and outcomes. METHODS AND RESULTS: Consenting adult patients undergoing elective radial cardiac catheterization were divided into palpation and US groups. Routine preprocedural assessment of radial artery characteristics was performed using handheld US. Baseline data, US findings, procedural outcomes, and clinical outcomes were compared in 182 participants (91 in each group). US guided radial access had significantly higher first pass success rates (76.92% vs. 49.45%, p 0.0001), fewer number of attempts (1.46 ± 1 vs. 1.99 ± 1.46, p 0.004), and shorter amount of time (93.62 ± 44.04 vs. 120.44 ± 67.1, p 0.002) compared with palpation guidance. The palpation group had significantly higher incidence of spasm (15.38% vs. 3.3%, p 0.0052). Subgroup analysis indicated consistent benefits of US guidance, especially in calcified radial arteries. CONCLUSION: This prospective, nonrandomized, single-center study demonstrated that real-time procedural US improved the operator's time and effort and enhanced patient comfort compared with palpation. US guidance use was particularly favorable in the presence of calcifications observed on baseline preoperative US.


Assuntos
Cateterismo Periférico , Adulto , Humanos , Estudos Prospectivos , Resultado do Tratamento , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Palpação/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Artéria Radial/diagnóstico por imagem , Artéria Radial/cirurgia , Ultrassonografia de Intervenção/métodos
11.
Surg Radiol Anat ; 46(4): 495-500, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38480592

RESUMO

The occurrence of variations in human arterial branching of the upper limb has been commonly reported in peer-reviewed literature. However, the variability of upper limb arterial patterns may be underappreciated in medical practice, which can result in clinical and surgical errors. Here we report a case of a rare, unilateral arterial variation of the left upper limb of a 76-year-old Caucasian male cadaver, discovered during a routine educational dissection. Observed characteristics of the variation include a high brachial artery bifurcation into a superficial brachioulnoradial artery and brachial artery continuing as the interosseous artery and then a bifurcation of the superficial brachioulnoradial artery into a superficial radial and a superficial ulnar artery, which eventually contribute to the formation of the superficial palmar arch. The anatomical characteristics, prevalence, embryological origin, and clinical significance of the variation are discussed.


Assuntos
Artéria Braquial , Artéria Ulnar , Masculino , Humanos , Idoso , Extremidade Superior , Braço/irrigação sanguínea , Dissecação , Cadáver , Artéria Radial
12.
Catheter Cardiovasc Interv ; 103(5): 731-735, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38494678

RESUMO

Catheter kinking is not an uncommon scenario during cardiac catheterization via transradial access in patients with tortuous vascular anatomy. Several noninvasive and invasive methods have been described to unkink and retrieve the kinked catheter out of the vessel. We present a novel mother-daughter technique to retrieve a kinked radial artery catheter.


Assuntos
Mães , Artéria Radial , Feminino , Humanos , Artéria Radial/diagnóstico por imagem , Núcleo Familiar , Angiografia Coronária , Resultado do Tratamento , Cateteres , Cateterismo Cardíaco/métodos
13.
BMC Nephrol ; 25(1): 105, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38500089

RESUMO

PURPOSE: The aim of this study was to investigate the effectiveness and safety of the pull-through technique through antegrade radial artery puncture without sheath insertion in balloon-assisted radiocephalic AVF maturation. METHODS: We retrospective studied a total of 62 patients with immature radiocephalic AVF, who received balloon-assisted maturation in our hospital. 15 patients received pull-through technique through radial artery without sheath insertion and 47 patients received treatment through a regular venous approach. RESULTS: The success rate of pull-through technique group and control group was 86.7% (13 out of 15), 89.1% (41 out of 46) respectively. There was no significant difference between two groups (P > 0.05). In our study, there were 2 patients in the pull-through technique group and 3 patients in the control group, which had hematoma in the vein puncture site (P = 0.59). There were also no differences in the primary patency rate between two groups at 6 months and 12 months (76.9% vs 70.7%, 38.4% vs 41.5%, respectively, P > 0.05). CONCLUSION: The pull-through technique through antegrade radial artery without sheath insertion in promoting radiocephalic AVF maturation is effective and safe.


Assuntos
Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Humanos , Artéria Radial/cirurgia , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Oclusão de Enxerto Vascular/etiologia , Grau de Desobstrução Vascular , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Diálise Renal/efeitos adversos , Fístula Arteriovenosa/etiologia , Punções
14.
J Korean Med Sci ; 39(10): e111, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38501187

RESUMO

BACKGROUND: The benefits of transradial access (TRA) over transfemoral access (TFA) for bifurcation percutaneous coronary intervention (PCI) are uncertain because of the limited availability of device selection. This study aimed to compare the procedural differences and the in-hospital and long-term outcomes of TRA and TFA for bifurcation PCI using second-generation drug-eluting stents (DESs). METHODS: Based on data from the Coronary Bifurcation Stenting Registry III, a retrospective registry of 2,648 patients undergoing bifurcation PCI with second-generation DES from 21 centers in South Korea, patients were categorized into the TRA group (n = 1,507) or the TFA group (n = 1,141). After propensity score matching (PSM), procedural differences, in-hospital outcomes, and device-oriented composite outcomes (DOCOs; a composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) were compared between the two groups (772 matched patients each group). RESULTS: Despite well-balanced baseline clinical and lesion characteristics after PSM, the use of the two-stent strategy (14.2% vs. 23.7%, P = 0.001) and the incidence of in-hospital adverse outcomes, primarily driven by access site complications (2.2% vs. 4.4%, P = 0.015), were significantly lower in the TRA group than in the TFA group. At the 5-year follow-up, the incidence of DOCOs was similar between the groups (6.3% vs. 7.1%, P = 0.639). CONCLUSION: The findings suggested that TRA may be safer than TFA for bifurcation PCI using second-generation DESs. Despite differences in treatment strategy, TRA was associated with similar long-term clinical outcomes as those of TFA. Therefore, TRA might be the preferred access for bifurcation PCI using second-generation DES. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03068494.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Artéria Radial , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
15.
Artigo em Alemão | MEDLINE | ID: mdl-38513644

RESUMO

Arterial catheterization is considered to be standard procedure for patients undergoing general anesthesia. The most common puncture site is the radial artery (RA), which carries a risk of RA occlusion. Several pieces of literature still recommend the performance of the Allen test (AT) to assess the circulation of the palmar arch. However, the result of the AT differs largely depending on the examiner and the test is not able to predict ischemic events correctly. Thus it appears that the performance of an AT is not mandatory before arterial cannulation.


Assuntos
Cateterismo Periférico , Artéria Radial , Humanos , Cateterismo , Mãos/irrigação sanguínea , Isquemia
16.
Zhonghua Xin Xue Guan Bing Za Zhi ; 52(3): 276-280, 2024 Mar 24.
Artigo em Chinês | MEDLINE | ID: mdl-38514329

RESUMO

Objective: To investigate the feasibility and safety of distal radial artery approach in emergency percutaneous coronary intervention(PCI) of elderly ST-segment elevation myocardial infarction(STEMI) patients. Methods: This study is a cross-sectional study. Elderly patients with acute myocardial infarction who received emergency PCI at the Third Central Hospital of Tianjin from January 2020 to December 2022 were selected. They were divided into the distal radial artery group and the classic radial artery group based on the puncture location. The success rate, puncture time, surgical success rate, and surgical time of the two groups were observed; The incidence of complications in patients, including radial artery occlusion rate, radial artery spasm rate, local hematoma rate, aneurysm incidence rate were recorded. Results: There were 70 cases in the distal radial artery group, including 33 males (47.1%), aged (65.6±6.7) years old; There were 70 cases in the classic radial artery group, including 35 males (50.0%), aged (66.4±6.9) years old. There was no statistically significant difference in puncture success rate, puncture time, surgical success rate, and surgical time between the distal radial artery group and the classical radial artery group (P>0.05). The incidence of radial artery occlusion in the distal radial artery group was significantly lower than that in the classical radial artery group (1.4% vs. 8.6%, P=0.024). The postoperative compression time in the distal radial artery group was significantly shorter than that in the classical radial artery group ((291.6±10.5) min vs. (343.5±9.8) min, P=0.047). There was no statistically significant difference in the incidence of radial artery spasm, local hematoma, and aneurysm between the two groups (P>0.05). Conclusions: The distal radial artery approach has a lower radial artery occlusion rate, shorter compression time, and better safety. It can be used as a new approach for emergency PCI in elderly patients with STEMI for clinical application.


Assuntos
Aneurisma , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Masculino , Idoso , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Artéria Radial/cirurgia , Estudos de Viabilidade , Estudos Transversais , Resultado do Tratamento , Hematoma , Espasmo
17.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 36(2): 208-210, 2024 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-38442941

RESUMO

Transradial approach is the classical access for coronary angiography and percutaneous coronary intervention (PCI). With the increase in the number of interventional procedures, some disadvantages of the transradial approach have also been found, it is easy to lead to various complications, such as radial artery occlusion, radial nerve injury, and puncture difficulties after radial artery spasm. Therefore, some experts put forward the approach of distal radial artery approach for interventional therapy, which has the advantages of convenient positioning, easy postoperative hemostasis, less damage to the proximal radial artery and improving patients' comfort. However, there is no special distal radial artery hemostat in clinic, which limits the development of this approach to a certain extent. Therefore, based on the principles of anatomy and physics, cardiovascular physician at Jiading District District Central Hospital in Shanghai designed and invented a distal radial artery hemostatic device, which is convenient for clinical hemostasis of distal radial artery puncture, and obtained the National Utility Model Patent (patent number: ZL 2021 2 2097829.6). The hemostatic device consists of a glove body with a silicone gasket protruding towards the skin on the inner surface and a binding component. The patient's hand is inserted into the glove body, and after being fixed by the restraint component, the silicone gasket can effectively compress the location of the radial artery puncture point, and play a good hemostatic effect with less pressure, avoid the common complications of proximal radial artery hemostatic, and reduce the discomfort of the patient. Has good application value.


Assuntos
Hemostáticos , Intervenção Coronária Percutânea , Humanos , Artéria Radial , China , Silicones
18.
J Vasc Access ; 25(2): 415-422, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38477132

RESUMO

Conventional transradial access has been established as the gold standard for invasive coronary angiography and percutaneous interventions by the current European and American guidelines. The distal or snuffbox radial artery access represents an alternative transradial access site that allows radial sheath insertion with the patient's hand pronated. Firstly described 40 years ago, it exploded in popularity only recently. Promising additional benefits, the distal radial access is increasingly being adopted in various types of percutaneous interventions, being preferred by many interventional cardiologists and radiologists for its reduced vascular complications and time to hemostasis, and improvement of patient and operator comfort. Other centers consider it a fad, waiting for solid clear evidence and benefits. The evidence is dynamic and discrepant, depending on the center, the operator, and how it was collected (randomized controlled vs observational studies). Another essential aspect raised by "skeptics" was whether distal radial access, by its smaller diameter and more angled course, can support all types of interventions. The aim of this review is to gather all the scenarios where distal radial access has been utilized and to conclude whether this vascular access is feasible across all transcatheter interventions.


Assuntos
Cateterismo Periférico , Intervenção Coronária Percutânea , Humanos , Artéria Radial , Angiografia Coronária/métodos , Intervenção Coronária Percutânea/métodos , Cateterismo Periférico/métodos , Mãos
19.
J Plast Reconstr Aesthet Surg ; 91: 111-118, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38412601

RESUMO

BACKGROUND: There is a lack of data regarding the baseline hemodynamic blood flow parameters of the wrist and digits. Therefore, we aimed to quantify the digital and radial artery blood flow parameters using ultrasound and assess the influence of patient characteristics on hemodynamics. METHODS: We analyzed ultrasonographic data from 25 patients (50 hands) between October 2019 and December 2021. Variables of interest included dimensions of the radial artery and index finger (IF) ulnar and radial digital arteries at the palmodigital crease and their corresponding flow parameters. We compared variables among men and women and patients with and without diabetes using Wilcoxon Rank Sum test. RESULTS: Our cohort consisted of 18 women (36 hands) and three participants with diabetes (six hands). The mean diameter of the IF radial digital artery was 7 mm, and that of the ulnar digital artery was 10 mm. The average peak systolic velocity for the radial digital artery was 21.31 cm/sec, and for the ulnar digital artery, it was 30.03 cm/sec. Comparing men and women, the only significant difference found was in the time-averaged mean velocity for the ulnar digital artery (men:5.66 cm/sec vs. women:9.68 cm/sec, P = 0.02) and volume of flow for the ulnar digital artery (men:10.87cc/min vs. women:18.58cc/min, P = 0.03). We found no differences in blood flow parameters comparing participants with and without diabetes. CONCLUSION: These data provide a baseline measurement of digital flow hemodynamics that can be used in future studies to model vascular flow after replantation.


Assuntos
Diabetes Mellitus , Artéria Ulnar , Masculino , Humanos , Feminino , Artéria Ulnar/diagnóstico por imagem , Hemodinâmica , Artéria Radial/diagnóstico por imagem , Punho , Velocidade do Fluxo Sanguíneo/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...